Fluke 85 Series III Digital Multimeter Specifications General Specifications DCV Maximum Voltage: 1000V Accuracy:
Fluke 83 III: ±(0.1%+1) Fluke 85 III: ±(0.08%+1) Fluke 87 III: ±(0.05%+1) Fluke 87/E: ±(0.05%+1) Maximum Resolution: 0.1 mV ACV Maximum Voltage: 1000V Accuracy: Fluke 83 III: ±(0.5%+2) Fluke 85 III: ±(0.7%+2) Fluke 87 III: ±(0.7%+2) Fluke 87/E: ±(0.7%+2) Maximum Resolution: 0.1 mV DC Current Maximum Amps: 10A Amps Accuracy: Fluke 83 III: ±(0.4%+2) Fluke 85 III: ±(0.2%+2) Fluke 87 III: ±(0.2%+2) Fluke 87/E: ±(0.2%+2) Maximum Resolution: Fluke 83 III: 0.01 mA Fluke 85 III: 0.1 µA Fluke 87 III: 0.1 µA Fluke 87/E: 0.1 µA AC Current Maximum Amps: 10A Amps Accuracy: Fluke 83 III: ±(1.2%+2) Fluke 85 III: ±(1.0%+2) Fluke 87 III: ±(1.0%+2) Fluke 87/E: ±(1.0%+2) Maximum Resolution: 0.1 µA Resistance Max Resistance: 40 MW Accuracy: Fluke 83 III: ±(0.4%+1) Fluke 85 III: ±(0.2%+1) Fluke 87 III: ±(0.2%+1) Fluke 87/E: ±(0.2%+1) Maximum Resolution: 0.1W Capacitance 1 nF-5µF Frequency 0.5 Hz to 200 kHz
Specifications & Attributes (Multimeter)
Measurements |
Capacitance
|
Current
|
Frequency
|
Resistance
|
Volts (AC)
|
Volts (DC)
|